OUTPUT
CHARACTERISTICS:
|
Output Voltage |
Regulation |
Output Current |
Ripple & Noise |
|
Load |
Line |
460W |
|
Min. |
Max. |
|
+5V |
±5% |
±1% |
5A |
40A |
60mV |
|
+12V |
±5% |
2.5A |
27A |
100mV |
|
+3.3V |
±5% |
1A |
30A |
60mV |
|
-5V |
±5% |
0A |
0.8A |
100mV |
|
-12V |
±5% |
0A |
1A |
100mV |
|
+5SVB |
±5% |
0.1A |
2A |
60mV |
|
Total output should not
exceed 460W for
TR-6460ACR |
|
Noise bandwidth: DC to
20MHz |
OVERALL PERFORMANCE:
Efficiency:
67% typical @ 115VAC
full load
Power Good Signal: On
delay 100ms~500ms, off
delay 1ms
Short Circuit Protection
(SCP):
Shutdown and latch
Over Load Protection (OLP): 110~150%
max.
Over Voltage Protection
(OVP): +5V:
5.7V~6.5V, +3.3V:
3.9V~4.3V, +12V:
13.6V~15V
Over Current
Protection (OCP): +5V:
44A~60A, +3.3V: 27.5A~37.5A,
12V: 29.1A~40.5A
Alarm Method:
1) Audio alarm, 2)Fault
LED indicator, 3) Power
defective signal
Hot-Swappable &
Hot-Pluggable Capability
ENVIRONMENTAL
SPECIFICATIONS:
Cooling:
Two 80mm
DC fans with ball bearings
Operating Temperature:
0°C~+50°C, +60°C
at half power
Operating Humidity:
20%~95% RH
(non-condensing)
Storage Temperature:
-10°C~+70°C
Storage Humidity:
10%~90% RH (non-condensing)
RELIABILITY:
MTBF:
>75,000
hours @ max. load & 25°C ambient
Safety Standards:
Meet UL1950, CSA
22.2NO/950, TUV IEC 950
EMI Compatibility
(EMC):
FCC
Part 15 Class B, CISPR22
(EN55022) Class B (CE
mark)
Dielectric Isolation:
Input to output: 3000VAC
for 1 minute,
Input to frame ground
1500VAC for 1 minute
STANDARD OUTPUT CABLE
LENGTH:
530mm
or 20.87 inches
ENCLOSURE
DIMENSIONS:
194.2(L) x
354(W) x 106(H)
mm
7.65(L) x 13.94(W) x
4.17(H) inches
NET WEIGHT:
4~4.6KG
8.8~10.14LB
|